ECUMC — Project Setup
This section configures the XCP on CAN example in VeriStand and prepares the screen used to control and monitor the demo ECU. Complete Installation first.
Configure the XCP or CCP Master in NI VeriStand
Add the custom device
After creating a VeriStand project, open System Explorer and add “XCP or CCP Master” under “Custom Devices”.

Select the A2L database and XCP transport
Select “XCP or CCP Master” to open its configuration UI, then select an A2L database file. An example database installed with ECUMC is located at:
C:\Program Files\NI\LVAddons\ecumc\1\examples\ECUMC\XcpECU.a2l
For this initial CAN example, select “XCP on CAN” from the “Master Type” dropdown.

Configure the CAN interface
Use the communication properties supplied by the example A2L database. Switch to the “CAN” tab, select the CAN port for the master endpoint (VeriStand), and enable “NI-XNET Bus Termination” for the demonstrated setup. No changes are required under “Miscellaneous”.

Add Characteristics
Select “Characteristics” beneath “XCP or CCP Master” in the tree view. Choose the available characteristics to add to the VeriStand channel list.
Characteristics represent ECU calibration parameters. They can be adjusted through the master when supported and permitted by the ECU.

Add Measurements
Select “Measurements1” to open the measurement configuration UI. Choose from “Available Measurements in Database” and add the required signals to the VeriStand channel list.
Important: Do not add MeasScalarU64 to this example configuration. The documented VeriStand setup does not support this signal type; including it causes the project to fail. This limitation should be rechecked if using a different toolkit or VeriStand version.
Measurements expose internal ECU values for observation and logging rather than calibration changes.

Save the configuration
Save the configuration and close System Explorer.
Create the VeriStand Screen
Add a screen
Add a new “Screen”.

Add PWM calibration controls
This example focuses on the software ECU’s PWM_Signal. Drag PWM_Frequency and PWM_Level from the tree view onto the screen panel. These characteristics control the frequency and level of the signal generated by the example ECU.

Add a chart
Right-click the screen panel, search for “chart”, and add a “Chart”.

Select the measurement for the chart
Use the “Data Source” button to select PWM_Signal from the available measurements.

The VeriStand project and screen are now prepared. Continue with Example Execution to start the demo ECU, deploy the project, and test the communication.