ECUMC — Example Execution

Use the project and VeriStand screen created in Project Setup. The example starts with XCP on CAN, followed by the XCP over TCP/UDP and CCP on CAN variants.

Start the Example ECU and Deploy

Launch the software ECU

Before deploying the VeriStand project, start the software ECU application. Search for “xcp” in the Windows Start menu and launch “NI ECUMC Demo ECU XCP”.

Finding NI ECUMC Demo ECU XCP in Windows Search

Configure the ECU CAN endpoint

By default, the demo ECU uses CAN2, assuming the XCP master is configured on CAN1. Connect CAN1 and CAN2 to the same physical CAN bus. In the documented two-node setup, enable “Termination” for the demo ECU as well as the master’s NI-XNET termination.

CAN requires termination at the two physical ends of the bus. The correct termination arrangement depends on the actual wiring; do not add extra termination if the bus is already terminated. Start the ECU.

ECUMC demo ECU configured for CAN2 and termination

Deploy VeriStand

Start the ECU first, then deploy the VeriStand project.

Deploying the ECUMC VeriStand project

Verify the PWM measurement

The chart should display a rectangular (PWM) signal. Changing PWM_Frequency or PWM_Level should cause the software ECU to change the generated signal accordingly, and the chart should reflect that change.

VeriStand screen showing the PWM measurement waveform

The basic XCP master example is now complete.

XCP over TCP/UDP

Change the master transport

In System Explorer, change “Master Type” to “XCP on TCP” or “XCP on UDP”. The selected transport must match the protocol configured in the software ECU, and the communication settings must match the applicable A2L configuration.

XCP Master Type choices for TCP and UDP

Change the software ECU transport

Stop the software ECU and select the corresponding “Protocol” option (TCP/IP or UDP/IP). Restart the software ECU using the matching transport settings.

Selecting TCP or UDP in the ECUMC Demo ECU application

For this example, the database specifies communication over localhost between the XCP master and slave. Both applications communicate through the local network stack, so no physical Ethernet loopback cable is needed. The rest of the VeriStand project remains unchanged.

CCP over CAN

Start the CCP Demo ECU

For CCP communication, use the separate software ECU provided with the NI ECU Measurement and Calibration Toolkit. Open Windows Search and search for CCP.

Start the NI ECUMC Demo ECU CCP application.

Windows Search showing NI ECUMC Demo ECU CCP

Configure the CCP Demo ECU

Select NI-XNET and configure the CAN interface. In this example, the software ECU uses CAN2, while the VeriStand CCP Master uses CAN1.

Enable Termination for the demo ECU, assuming these interfaces are connected at opposite ends of the CAN bus. Leave the remaining settings at their default values.

NI ECUMC Demo ECU CCP CAN interface and termination settings

Configure the CCP Master in VeriStand

Return to the XCP or CCP Master Custom Device in VeriStand System Explorer.

  1. Change the Database to CCPECU.a2l, located in the same directory as the XCP example database:

    C:\Program Files\NI\LVAddons\ecumc\1\examples\ECUMC\CCPECU.a2l
    
  2. Change Master Type to CCP.
  3. Use the communication properties from the selected A2L database and verify that the master’s CAN interface matches the physical setup.

VeriStand CCP Master configuration with CCPECU A2L database

Run the CCP Example

Start the NI ECUMC Demo ECU CCP application before deploying the VeriStand project.

The remaining procedure follows the XCP on CAN example: configure the desired measurements and characteristics, deploy the project, and observe or modify ECU variables using the VeriStand screen.