Automotive Ethernet (VCOM)

Add VCOM to VeriStand

After creating a VeriStand project, open System Explorer and add “VCOM” under “Custom Device”.

Adding VCOM as VeriStand custom device

Open the VCOM Configurator

Select the newly added custom device and open the VCOM Configuration UI.

Opening VCOM Configuration UI

Configure general settings

The top section contains general settings. The following adjustments are optional:

  1. Debug Level

    • Debug Level: 2 (default) -> least amount of information in the VCOM log files

    • Debug Level: 1 -> more debug information

    • Debug Level: 0 -> most detailed log files

  2. SysClock - “Timer Period(us)”

    • 10000 µs (default)

    • Determines the loop iteration time of the VCOM engine

    • This base time is the fastest possible cyclic output for the VCOM session

    • Under Windows: 10000 µs is common and useful. 5000 µs is possible. Not recommended to go lower than that

    • Under Linux: If needed 1000 µs possible

VCOM general settings and timing

Add the Ethernet function module

For the Rest-Bus Simulation configuration, add “Ethernet” under “Function Modules”.

Adding Ethernet function module

Select Automotive Ethernet

Add “Automotive Ethernet”.

Selecting Automotive Ethernet

Add a Hardware Port

Next, add a “Hardware Port” for each Automotive Ethernet port participating in the Rest-Bus Simulation. Existing port configurations can be duplicated.

Adding Automotive Ethernet hardware port

Configure the Automotive Ethernet Hardware Port

Select the newly created “Hardware Port” to open its settings. In most cases, the following three parameters are sufficient:

  1. Network descriptor (ARXML in this example; DBC and LDF are also supported):
    • Browse for the network descriptor file.
    • Confirm the selected descriptor file.
  2. Cluster Name: After loading the descriptor, the dropdown is populated with the available clusters. Select the cluster containing the PDUs or services to be used in the RBS.
  3. HW Port: Enter the alias of the Automotive Ethernet port, as listed in NI-MAX.

Loading Automotive Ethernet network descriptor

Automotive Ethernet hardware port settings

Configure the Peers

Add a “TX Peer” if the Hardware Port is intended to transmit messages. Add an “RX Peer” if the Hardware Port is intended to receive messages. Always add “AEthernet Peer” to your “HardwarePort”

Adding Automotive Ethernet peers

Add a Channel

Next, add a “Channel” to select the network containing the relevant ECU descriptions.

Adding network channel

Configure the Channel

Select the newly added Channel to open its settings.

The dropdown next to “Name” lists the networks in the previously selected cluster. Select the network to use for the RBS.

Selecting network name

Add an ECU

Add at least one “ECU” to the newly created Channel, then select it to open its settings.

Adding ECU to channel

Select the ECU

Select an “ECU” from the first dropdown menu, which lists the ECUs in the previously selected network.

Selecting ECU

The ECU name is the only mandatory setting in this UI.

Set optional network addresses

If the ARXML file does not contain network address information, or if you need to override the addresses from the descriptor, use the following settings (example values).

ECU IP and SOME/IP Service Discovery address settings

(VCOM 2026 Q4 shipped example ARXML does not require these settings. Any VCOM version older than 2026 Q4 does require these settings to be set.)

Configure the simulated ECUs

Keep adding ECUs to your configuration as your RBS requires. For the shipped example from VCOM adding “GW” and “VCU” as ECUs would be a valid choice. “GW” (TX) would then send out SOME/IP messages and “VCU” (RX) would receive those.

For a simple loopback demo application add one ECU to your first AE port and the next ECU to your second AE port. (It would also work if you added both ECUs to the same port as well.)

Automotive Ethernet loopback ECU configuration

Save the VCOM configuration

The basic VCOM configuration is complete. Click “Save” in the upper-right corner, confirm that the configuration was saved, and close the configurator.

Saving VCOM configuration

Confirm the signal selection

After closing the configurator, the VCOM custom device checks for any changes to the signal list. The user has now the chance to select specific portions of the signal list to optimize performance. Unused signals will just create overhead to the overall execution. For the simple demo configuration just press “Done” without changing anything to the signal list.

Selecting VCOM signals

Save the VeriStand system definition

Click the “Save” icon and close System Explorer.

The tree view on the left contains the available signals and “VCOM – Status”. Next, create a new screen.

Creating VeriStand screen

Monitor VCOM status

Drag and drop the “VCOM Status” from the tree view on the left onto your new screen panel. The “VCOM – Status” information is particularly useful for the very first runs of your VCOM configuration (besides the VCOM log files) to get immediate feedback about the execution state of the VCOM engine.

VCOM status panel

The three most relevant items from “Status” are:

  1. State: Indicates the current state of the VCOM engine:
    • “Idle”: Initial value
    • “Starting”
    • “Running”
    • “Stopping”
    • “Error”
  2. Overrun Count: Counts VCOM loop iterations that take longer than the configured loop period. A few overruns may occur during initialization, but the count should not increase continuously. If it does, reduce the signal count to improve performance. If the VCOM loop cannot maintain its configured timing, RBS output timing will be inaccurate.
  3. RE_StepAll: The sum of the time-consuming function calls within one VCOM engine iteration, in µs. This value should be lower than “Execution Time”, which measures the actual loop iteration time. “Execution Time” targets the configured SysClock “Timer Period(us)” under “General Settings”.

Review the signal hierarchy

The tree view on the left shows the hierarchy of the Rest-Bus Simulation configuration. The shipped example contains the following representative structure.

Automotive Ethernet signal hierarchy

Enable transmissions

VCOM adds the so called “TX_enable” signals (besides others) to the actual signals described in the database. These “TX_enable” signals will activate the specific portion of the Restbus configuration. To activate a specific service or PDU you need to set the according “TX_enable” signal to “1” but also all other “TX_enable” signals in the whole path from “HW Port” down to the PDU. A typical hierarchy is:

  1. HW Port (yellow)

  2. ECU (green)

  3. Service (red)

  4. PDU (purple)

Within VCOM, setting “TX_enable” to “1” enables the configured communication behavior. In the SOME/IP Service Discovery context, this corresponds to:

  • For “ConsumedServices”, subscribing to a service

  • For “ProvidedServices”, offering a service for subscription

These offer and subscription mechanisms are part of SOME/IP Service Discovery.

Review the receiving peer

Here the example for the RX_Peer port of the loop-back demo (PDU level does not require a “TX_enable” as the subscription happens on service level).

Receiving peer signal hierarchy

Deploy the VeriStand project

Drag all relevant “TX_enable” signals and PDUs onto the screen panel. Click the “Idle” icon in the upper-left corner and deploy the project.

Deploying VeriStand project

Start the communication

After deployment finishes, set all “TX_enable” signals (blue) to “1”.

Automotive Ethernet loopback signals and status

Once all “TX_enable” signals are set to “1”, the TX_Peer starts transmitting cyclic PDU messages at the configured cycle time (here: 250 ms). The Kickout signal can trigger PDU transmission independently of the cyclic timing. Some PDUs may only be transmitted when triggered by the “TX_kickout” signal.