Analog Input, Low-Current with FIU (CompactHIL)

Analog input to acquire voltage measurement normally dedicated to sensors or signals provided by the ECU. In combination with the Wireflow Module WF 3154 Fault Insertion capabilities can be added for 4 channels per module. The fault insertion module will provide short to RAIL (A/B) and Open Circuit fault capabilities for each channel connected to it.

WF_FIU_Module

Voltage Attributes

Attribute Value
Channels/signal path 32
Voltage ±10 V
Resolution 16 bit
FIU Channels per module 4
FIU Current 2.5A
Max Voltage 58V

Voltage Components

Component Model Specification Part Number
C Series Module NI 9205 NI-9205  Specifications 779357-01
Connector NI 9923 NI-9923 Dimensional Drawings - NI 781503-01
FIU Module WF 3154 WF 3154 Specifications -

Current Attributes

Attribute Value
Channels/signal path 8
Current ±20mA
Resolution 24bit
FIU Channels per module 4
FIU Current 2.5A
Max Voltage 58V

Current Components

Component Model Specification Part Number
C Series Module NI 9253 NI-9253 Specifications - NI 785989-01
FIU Module WF 3154 WF 3154 Specifications -