RestBus Simulation
RestBus Simulation (RBS) in automotive HIL testing means simulating the ECUs and network participants that are missing from the physical test setup.
A modern vehicle contains many ECUs communicating over networks such as CAN, CAN FD, LIN and Automotive Ethernet. When testing one ECU in a Hardware-in-the-Loop system, you normally do not connect the entire vehicle. Instead, the HIL system simulates the communication behavior of the surrounding ECUs so that the Device Under Test sees a realistic vehicle environment.
The simulated ECUs typically transmit cyclic messages, react to messages from the DUT, provide expected signal values, implement counters/checksums, reproduce network-management behavior, and sometimes provide higher-level services such as diagnostics or SOME/IP communication.
For a CAN-based ECU, an RBS might simulate something simple such as:
-
ABS ECU -> VehicleSpeed = 80 km/h
-
BCM ECU -> IgnitionState = ON
-
Gateway -> AliveCounter = 0…15
-
ADAS ECU -> DriverAssistAvailable = TRUE
The HIL sends these frames at the correct cycle times, for example every 10 ms or 100 ms. The DUT therefore behaves as though those real ECUs were physically connected.
With Automotive Ethernet, the principle is the same, but the communication stack is more complex. RBS may include:
-
Ethernet/IP configuration
-
VLANs
-
UDP/TCP communication
-
SOME/IP services and events
-
SOME/IP Service Discovery
-
E2E protection
-
SOME/IP-TP segmentation
-
network-management behavior
HIL = the complete real-time test environment
RBS is therefore normally one subsystem of a HIL system. Other parts of the HIL may simulate sensors, actuators, electrical loads, power supplies, fault insertion, vehicle dynamics, or plant models.